| Government & Education Departments APC has recently introduced a special offer for Government & Education Departments. Please click on the "Enquire" button above to request a Gov or Edu quotation for the items required (Conditions Apply) |
| Basic Rack Power Distribution Units (PDU's) | Metered Rack Power Distribution Units (PDU's) | ||
| Switched Rack Power Distribution Units (PDU's) | Rack Automatic Transfer Switch (ATS) | ||
| Rack PDU Accessories | |||
|
|
|||||
| Basic Rack Power Distribution Units (PDU's) | |||||
|
Power
distribution for rack-mount equipment. |
|||||
|
|
|||||
| 120V, 200V, 208V, 230V Input | |||||
|
|
|||||
| AP9559 | APC Rack PDU, Basic, 1U, 16A, 208&230V, (10) C13 & (2) C19 | $384 | |||
| APC Basic Rack
PDU, Input: 120V, 208V, 230V, Input Connections: IEC-320 C20, Cord Length:
2.5 metres (8.2 feet), Output: 120V, 208V, 230V, Output Connections: 10 x IEC 320 C13,
2 x IEC 320 C19. Plug
Specs Includes: Rack Mounting Brackets, User Manual. |
|||||
|
|
|||||
|
|
|||||
| 200V, 208V, 230V Input | |||||
|
|
|||||
| AP7551 | APC Rack PDU, Basic, Zero U, 16A, 230V, (20) C13 & (4) C19; IEC309 | $426 | |||
|
|
The American Power Conversionฎ AP7551 Basic Rack PDU distributes power to devices in the rack. The Rack PDU has twenty (20) IEC-320-C13 outlets, and four (4) IEC-320-C19 outlets. The 3-foot (0.91-meter) power cord terminates with a IEC-309 16 A connector. |
||||
|
APC Basic Rack PDU
Toolless mounting capabilities Vertical Mounting Capabilities Cord Length: 0.91 metres (3 feet) Output: 230V Output Connections: 20 x IEC 320 C13, 4 x IEC 320 C19 |
Input: 230V Input Connections: IEC 309 16A 2P+E Includes: Installation Guide Tool-less Mounting Kit Plug Specs |
||||
|
|
|||||
|
|
|||||
| AP7552 | APC Rack PDU, Basic, Zero U, 16A, 230V, (20) C13 & (4) C19; IEC C20 | $426 | |||
|
|
The American Power Conversionฎ AP7552 Basic Rack PDU distributes power to devices in the rack. The Rack PDU has twenty (20) IEC-320-C13 outlets, and four (4) IEC-320-C19 outlets. The 10-foot (3.05-meter) power cord terminates with an IEC-320-C20 connector. |
||||
|
APC Basic Rack
PDU Vertical Mount Input: 230V Input Connections: IEC-320 C20 Cord Length: 3.05 metres (10 feet) Output Connections: 20 x IEC 320 C13, 4 x IEC 320 C19 |
Output: 230V
Includes: Installation Guide Tool-less Mounting Kit Plug Specs |
||||
|
|
|||||
|
|
|||||
| AP7553 | APC Rack PDU, Basic, Zero U, 32A, 230V, (20) C13 & (4) C19 | $458 | |||
|
|
The APC AP7553 Basic Rack PDU distributes power to devices in the rack. The Rack PDU has twenty IEC-320-C13 outlets, and four IEC-320-C19 outlets. The 10-foot (3.05-meter) power cord terminates with a IEC-309 32 A connector. |
||||
|
APC Basic Rack
PDU Input: 230V Input Connections: IEC 309 32A 2P+E Cord Length: 3.05 m (10 feet) Output: 230V Output Connections: 20 x IEC 320 C13, 4 x IEC 320 C19 |
Includes:
Installation Guide Rack Mounting Brackets Tool less Mounting Kit Plug Specs |
||||
|
|
|||||
|
|
|||||
| AP7554 | APC Rack PDU,Basic,ZeroU,16A,230V,(20) C13 & (4) C19; IEC309, 10 ft Cord | $478 | |||
|
|
The American Power Conversion (APCฎ) AP7554 Basic Rack Power Distribution Unit (PDU) distributes power to devices in the rack. The Rack PDU has twenty (20) IEC-320-C13 outlets and four (4) IEC-320-C19 outlets. The 10-foot (3.05-meter) power cord terminates with a IEC-309 16A connector. |
||||
| APC Basic Rack PDU, Input: 230V, Input Connections: IEC 309 16A, Cord Length: 10 feet (3.05
metres), Output: 230V , Output Connections: IEC 320 C13,IEC 320 C19.
Plug Specs Includes: Installation guide, Rack Mounting brackets, Toolless Mounting Kit |
|||||
|
|
|||||
|
|
|||||
| AP7585 | APC Rack PDU Extender, Basic, 2U, 32A, 230V, (4) IEC C19 | $674 | |||
| APC Basic Rack PDU , Input: 230V , Input Connections: Hard Wire 3-wire , Cord Length: 8.53
metres ( 28 feet ) , Output: 230V , Output Connections: IEC 320 C19 -
Includes:
Installation Guide
Rack Mounting Brackets. Plug Specs |
|||||
|
|
|||||
|
|
|||||
| AP7586 | APC Rack PDU Extender, Basic, 2U, 32A, 230V, (4) IEC 309-32 | $842 | |||
| APC Basic Rack
PDU,
Input: 230V, Input Connections: Hard Wire 3-wire, Cord Length: 8.53 metres (28 feet), Output: 230V, Output Connections:
4 x IEC 309. Plug
Specs Includes: Installation Guide Rack Mounting Brackets. |
|||||
|
|
|||||
|
|
|||||
| AP9565 | APC Rack PDU, Basic, 1U, 16A, 208/230V, (12) C13 | $237 | |||
| APC Basic Rack
PDU,
Input: 208V, 230V, Input Connections: IEC-320 C20, Cord Length: 2.5 metres (8.2 feet), Output: 208V, 230V, Output Connections:
12 x IEC 320 C13. Plug
Specs Includes: Installation Guide, Rack Mounting Brackets. |
|||||
|
|
|||||
|
|
|||||
| AP9568 | APC Rack PDU, Basic, Zero U, 10A, 230V, (15) C13 | $292 | |||
| APC Basic Rack
PDU,
Input: 208V, 230V, Input Connections: IEC-320 C14, Cord Length: 1.98 metres (6.5 feet), Output: 208V, 230V, Output Connections:
15 x IEC 320 C13. Plug
Specs Includes: Installation Guide, Rack Mounting Brackets, Tool less Mounting Kit. |
|||||
|
|
|||||
|
|
|||||
| AP9572 | APC Rack PDU, Basic, Zero U, 16A, 208/230V, (15) C13 | $298 | |||
| APC Basic Rack
PDU,
Input: 120V, 208V, 230V, Input Connections: IEC-320 C20, Cord Length: 2.5
metres (8.2 feet), Output: 120V, 208V, 230V, Output Connections: 15 x IEC 320 C13.
Plug Specs Includes: Rack Mounting Brackets, User Manual. |
|||||
|
|
|||||
|
|
|||||
| 400V 3Phase Input | |||||
|
|
|||||
| AP7526 | APC Rack PDU, Basic, 1U, 22kW, 400V, (6) C19 | $777 | |||
|
|
The American Power Conversion (APCฎ) AP7526 Basic Rack Power Distribution Unit (PDU) for Blade Servers distributes power to devices in the rack. The PDU has six (6) IEC-320-C19 outlets. The 8-ft (2.43-m) power cord terminates with an IEC-309 32 A connector. |
||||
| APC Basic Rack PDU , Input: 400V 3PH , Input Connections: IEC 309 32A 3P+N+PE , Cord Length: 8 feet ( 2.44 meters ) , Output: 230V , Output Connections: IEC 320 C19. Includes: Installation guide Plug Specs | |||||
|
|
|||||
|
|
|||||
| AP7555 | APC Rack PDU, Basic, Zero U, 22kW, 400V, (6) C19 & (3) C13 | $924 | |||
|
|
APC Basic Rack PDU , Input: 400V 3PH , Input Connections: IEC 309 32A 3P+N+PE , Cord Length: 6 feet ( 1.83 meters ) , Output: 230V , Output Connections: IEC 320
C13, IEC 320 C19. Plug
Specs Includes: Installation guide, Toolless Mounting Kit |
||||
|
|
|||||
|
|
|||||
| AP7557 | APC Rack PDU, Basic, Zero U, 11 kW, 230V, (36) C13 & (6) C19 | $884 | |||
|
|
APC Basic Rack PDU
Low Cost Power Distribution Multi-branch power input Cord Length: 0.91 metres ( 3 feet ) Input: 400V 3PH Input Connections: IEC 309 16A 3P+N+PE Output: 230V Output Connections: IEC 320 C13, IEC 320 C19 |
Toolless mounting capability Vertical mounting capability Includes: Installation guide, Rack Mounting brackets, Toolless Mounting Kit, User Manual 2 years repair or replace Warranty |
|||
|
|
|||||
| Metered Rack Power Distribution Units (PDU's) | |||||
|
Metered rack PDUs provide real-time remote monitoring of connected loads. User-defined alarms warn of potential circuit overloads before critical IT failures occur - APC Metered Rack Power Distribution Units (PDUs) provide advanced warning to protect against unplanned power overloads. User-defined alarm thresholds mitigate risk with real-time local and remote alerts of potential unexpected circuit overloads to your mission critical equipment. Metered rack PDUs provides power utilization trends allowing Data Centre Managers to make informed decisions on right sizing IT environments to lower total cost of ownership. Users can access and configure Metered rack PDUs through secure Web, SNMP, or Telnet Interfaces and is complimented by APC Centralized Management platforms using InfraStruXure Manager, InfraStruXure Central, Capacity Manager & Change Manager. |
|||||
|
|
|||||
| 230V Input | |||||
|
|
|||||
| AP7152 | APC In-Line Current Meter, 16A, 230V, IEC309-16A, 2P+G | $459 | |||
|
|
The APC In-Line Current Meter AP7152 monitors current to devices in the datacentre including existing Basic Rack Power Distribution Units (PDUs) and freestanding equipment. The Current Meter has a sensor that measures the current that it and its attached devices use. The Current Meter can be monitored through Web, Telnet, SNMP, SSH, or InfraStruXureฎ Manager and Central interfaces. A digital display shows aggregate current being used per phase by the Current Meter. Power cords. Each 0.91-m (3-ft) power cord terminates with an IEC 309, 16-A, 2P+PE connector. Includes: Documentation CD, Rack Mounting brackets, RS-232 configuration cable. |
||||
|
|
|||||
|
|
|||||
| AP7155 | APC In-Line Current Meter, 32A, 230V, IEC309 | $502 | |||
|
|
Network Management: Provides proactive power and environmental management via web and/or SNMP. Flash Upgradeable: Quickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only). Single input power source: Supply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time & money during installation by using one branch whip & standard connections. Alarm Thresholds: Define alarm thresholds in order to avoid overloaded circuits. Network & visual alarms inform the user of possible problems. (Note: Only available on units with the current monitoring capabilities. The APC In-Line Current Meter monitors current to devices in the datacenter including existing basic rack PDUs and freestanding equipment. Includes: Documentation CD, Rack Mounting brackets, RS-232 configuration cable. |
||||
|
|
|||||
|
|
|||||
| AP7820 | APC Rack PDU, Metered, 1U, 12A/208V, 10A/230V, (8) C13 | $467 | |||
|
|
The American Power Conversion (APCฎ) AP7820 Metered Rack Power Distribution Unit (PDU) distributes power to devices in the rack. It has a sensor that measures the current used by the PDU and its attached devices. It can be monitored through Web, Telnet, SNMP, SSH, or InfraStruXureฎ Manager interfaces. The PDU has eight (8) IEC-C13 outlets. Digital display. A digital display shows aggregate current being used per phase by the PDU. The power cord terminates with a IEC-C14 connector. |
||||
| APC Metered Rack PDU , Input: 208V, 230V , Input Connections: IEC-320 C14 , Output: 208V, 230V , Output Connections: IEC 320 C13 Includes: Cord retention bracket(s), Installation guide, Rack Mounting brackets, User Manual 2 years repair or replace. Plug Specs | |||||
|
|
|||||
|
|
|||||
| AP7821 | APC Rack PDU, Metered, 1U, 12A/208V, 10A/230V, (8) C13 | $512 | |||
|
|
The American Power Conversion (APCฎ) AP7821 Metered Rack Power Distribution Unit (PDU) distributes power to devices in the rack. It has a sensor that measures the current used by the PDU and its attached devices. It can be monitored through Web, Telnet, SNMP, SSH, or InfraStruXureฎ Manager interfaces. The PDU has eight (8) IEC-C13 outlets. Digital display. A digital display shows aggregate current being used per phase by the PDU. The power cord terminates with a IEC-C20 connector. |
||||
| APC Metered Rack PDU , Input: 200V, 230V , Input Connections: IEC-320 C20 , Output: 208V, 230V , Output Connections: IEC 320 C13 Includes: Cord retention bracket(s), Installation guide, Rack Mounting brackets, User Manual 2 years repair or replace. Plug Specs | |||||
|
|
|||||
|
|
|||||
| AP7822 | APC RACK PDU, Metered, 2U, 32A, 230V, (12) C13S & (4) C19 | $861 | |||
|
|
The American Power Conversion (APCฎ) AP7822 Metered Rack Power Distribution Unit (PDU) distributes power to devices in the rack. It has a sensor that measures the current used by the PDU and its attached devices. It can be monitored through Web, Telnet, SNMP, SSH, or InfraStruXureฎ Manager interfaces. The PDU has twelve (12) IEC-C13 outlets and four (4) IEC-C19 outlets. Digital display. A digital display shows aggregate current being used per bank by the PDU. The 12-ft (3.65-m) power cord terminates with an IEC-309 32-A connector. |
||||
| APC Metered Rack PDU , Input: 230V , Input Connections: IEC 309 32A 2P+E , Cord Length: 3.66
metres (12 ft) , Output: 200V , Output Connections: IEC 320 C13,IEC 320 C19.
Plug Specs Includes: Cord retention bracket(s), Installation guide, Rack Mounting brackets, User Manual |
|||||
|
|
|||||
|
|
|||||
| AP7850 | APC Rack PDU, Metered, Zero U, 10A, 230V, (16) C13 | $564 | |||
|
|
The APC AP7850 Metered Rack PDU distributes power to devices in the rack. It has a sensor that measures the current used by the PDU and its attached devices. The PDU can be monitored through Web, Telnet, SNMP, SSH, or InfraStruXure Manager interfaces. The Rack PDU has sixteen (16) IEC-320-C13 outlets. Display interface. A digital display shows the aggregate current used by the Rack PDU. The 10-foot (3.05-meter) power cord terminates with an IEC-320-C14 connector. |
||||
| APC Metered Rack
PDU Input: 230V Input Connections: IEC-320 C14 Cord Length: 3.05 metres (10 feet) Output: 230V Output Connections: 16 x IEC 320 C13 |
Includes:
Cord Retention Bracket(s) Installation Guide Rack Mounting Brackets Tool less Mounting Kit Plug Specs |
||||
|
|
|||||
|
|
|||||
| AP7851 | APC RackPDU, Metered, ZeroU, 16A, 230V, (20) C13 & (4) C19; IEC309 | $663 | |||
|
|
The APC AP7851 Metered Rack PDU distributes power to devices in the rack. It has a sensor that measures the current that it and its attached devices use. It can be monitored through Web, Telnet, SNMP, SSH, or InfraStruXure Manager interfaces. The Rack PDU has twenty (20) IEC-320-C13 outlets and four (4) IEC-320-C19 outlets. Display interface. A digital display shows aggregate current being used by the Rack PDU. The 3-foot (0.91-meter) power cord terminates with a IEC 309 1~230 V 16A connector. |
||||
|
APC Metered Rack
PDU Input: 230V Input Connections: IEC 309 16A 2P+E Cord Length: 0.91 metres (3 feet) Output: 230V Output Connections: 20 x IEC 320 C13, 4 x IEC 320 C19 |
Includes:
Installation Guide Rack Mounting Brackets Tool less Mounting Kit User Manual Plug Specs |
||||
|
|
|||||
|
|
|||||
| AP7852 | APC RackPDU, Metered, ZeroU, 16A, 230V, (20) C13 & (4) C19; IEC C20 | $661 | |||
|
|
The APC AP7852 Metered Rack PDU distributes power to devices in the rack. It has a sensor that measures the current that it and its attached devices use. It can be monitored through Web, Telnet, SNMP, SSH, or InfraStruXure Manager interfaces. The Rack PDU has twenty (20) IEC-320-C13 outlets and four (4) IEC-320-C19 outlets. Display interface. A digital display shows aggregate current being used by the Rack PDU. The 10-foot (3.05-meter) power cord terminates with a IEC-320-C20 16A connector. |
||||
|
APC Metered Rack
PDU Input: 230V Input Connections: IEC-320 C20 Cord Length: 10 feet ( 3.05 metres) Output: 230V Output Connections: 20 x IEC 320 C13, 4 x IEC 320 C19 |
Includes:
Installation Guide Rack Mounting Brackets Tool less Mounting Kit User Manual Plug Specs |
||||
|
|
|||||
|
|
|||||
| AP7853 | APC Rack PDU, Metered, Zero U, 32A, 230V, (20) C13 & (4) C19 | $678 | |||
|
|
The APC AP7853 Metered Rack Power Distribution Unit (PDU) distributes power to devices in the rack. It has a sensor that measures the current that it and its attached devices use. It can be monitored through Web, Telnet, SNMP, SSH, or InfraStruXureManager interfaces. The Rack PDU has twenty (20) IEC-320-C13 outlets and four (4) IEC-320-C19 outlets. Display Interface. A digital display shows aggregate current being used by the Rack PDU. The 10-foot (3.05-meter) power cord terminates with a IEC-309 32 A connector. |
||||
|
APC Metered Rack
PDU Input: 230V Input Connections: IEC 309 32A 2P+E Cord Length: 3.05 metres (10 feet) Output: 230V Output Connections: 20 x IEC 320 C13, 4 x IEC 320 C19 |
Includes:
Installation Guide Rack Mounting Brackets Tool less Mounting Kit Plug Specs |
||||
|
|
|||||
|
|
|||||
| AP7854 | APC RackPDU, Metered, Zero U, 16A, 230V, (20) C13 & (4) C19 | $714 | |||
|
|
The APC AP7854 Metered Rack Power Distribution Unit (PDU) distributes power to devices in the rack. It has a sensor that measures the current used by the PDU and its attached devices. It can be monitored through Web, Telnet, SNMP, SSH, or InfraStruXure Manager interfaces. The Rack PDU has twenty (20) IEC-320-C13 outlets and four (4) IEC-320-C19 outlets. Display interface. A digital display shows the aggregate current being used by the Rack PDU. The 3.05-meter (10-foot) power cord terminates with a IEC-309 16A connector. |
||||
|
APC Metered Rack
PDU
Flash Upgradeable Remote Management Capabilities Toolless mounting capability Vertical mounting capability Cord Length: 3.05 meters (10 feet) Output: 230V Output Connections: 20 x IEC 320 C13, 4 x IEC 320 C19 |
Input: 230V Input Connections: IEC 309 16A 2P+E Includes: Installation Guide Rack Mounting Brackets Tool less Mounting Kit Plug Specs |
||||
|
|
|||||
|
|
|||||
| 230V / 400V 3Phase Input | |||||
|
|
|||||
| AP7175 | APC In-Line Current Meter, 32A, 230V, IEC309-32A 3-PH, 3P+N+G | $620 | |||
|
|
The APC In-Line Current Meter monitors current to devices in the datacentre including existing Basic Rack Power Distribution Units (PDUs) and freestanding equipment. The Current Meter has a sensor that measures the current that it and its attached devices use. The Current Meter can be monitored through Web, Telnet, SNMP, SSH, or InfraStruXureฎ Manager and Central interfaces. Digital display. A digital display shows aggregate current being used per phase by the Current Meter. Power cords. Each 0.91-m (3-ft) power cord terminates with an IEC 309, 32-A, 3P+N+PE connector. Includes: Documentation CD, Rack Mounting brackets, RS-232 configuration cable. |
||||
|
|
|||||
|
|
|||||
| AP7855A | APC Rack PDU, Metered, Zero U, 22kW, 400V, (6) C19 | $1,332 | |||
|
|
The APC AP7855A Metered Rack PDU for Blade Servers distributes power to devices in the rack. It has a sensor that measures the current that it and its attached devices use. It can be monitored through Web, Telnet, SNMP, SSH, or InfraStruXure Manager interfaces. The PDU has six (6) IEC-320-C19 outlets. Digital display. A digital display shows aggregate current being used per phase and the current being used per outlet by the PDU. The 6-foot (1.82-meter) power cord terminates with a IEC-309 connector. |
||||
|
APC Metered Rack PDU Flash Upgradeable High Power Density Information Displays Network Management Remote Current Monitoring Toolless mounting capabilities Vertical Mounting Capabilities Input: 400V 3PH Input Connections: IEC 309 32A 3P+N+PE Cord Length: 1.83 metres ( 6 feet ) |
Output: 230V Output Connections: IEC 320 C19 Includes: Cord retention bracket(s) Documentation CD Installation guide Rack Mounting Brackets RS-232 configuration cable 2 years repair or replace Warranty Plug Specs |
||||
|
|
|||||
|
|
|||||
| AP7856 | APC Rack PDU, Metered, Zero U, 22kW, 230V, (12) C19 & (6) C13 | $2,295 | |||
|
|
The APC AP7856 Metered Rack PDU distributes power to devices in the rack. It has a sensor that measures the current that it & its attached devices use. It can be monitored through Web, Telnet, SNMP, SSH, or InfraStruXureฎ Central interfaces. Outlets. The Rack PDU has six (6) IEC-320-C13 & twelve (12) IEC-320-C19 outlets. Digital display. A digital display shows aggregate current being used per phase & the current being used per bank by the Rack PDU. Power cord. The 0.91-m (3-ft) power cord terminates with an IEC 309, 32-A 3P+N+PE connector. APC Metered Rack PDU , Input: 400V 3PH , Input Connections: IEC 309 32A 3P+N+PE , Cord Length: 3 feet (0.91 meters ) , Output: 230V , Output Connections: IEC 320 C13,IEC 320 C19. Includes: Documentation CD, Installation guide, Rack Mounting brackets, RS-232 configuration cable, 2 years repair or replace Warranty card. |
||||
|
|
|||||
|
|
|||||
| AP7856A | APC Rack PDU, Metered, Zero U, 22kW, 230V, (12) C19 & (6) C13, 6FT Cord | $2,146 | |||
|
|
The APC AP7856A Metered Rack PDU distributes power to devices in the rack. It has a sensor that measures the current that it & its attached devices use. It can be monitored through Web, Telnet, SNMP, SSH, or InfraStruXureฎ Central interfaces. The Rack PDU has six (6) IEC-320-C13 & twelve (12) IEC-320-C19 outlets. Digital display. A digital display shows aggregate current being used per phase & the current being used per bank by the Rack PDU. The 1.82-m (6-ft) power cord terminates with an IEC 309, 32-A 3P+N+PE connector. APC Metered Rack PDU, Input: 400V 3PH , Input Connections: IEC 309 32A 3P+N+PE , Cord Length: 6 feet ( 1.83 meters ) , Output: 230V , Output Connections: IEC 320 C13,IEC 320 C19. Includes: Documentation CD, Installation guide, Rack Mounting brackets, RS-232 configuration cable, Warranty card.2 years repair or replace Warranty card. |
||||
|
|
|||||
|
|
|||||
| AP7857 | APC Rack PDU, Metered, Zero U, 11kW, 230V, (36) C13 & (6) C19 | $1,195 | |||
|
|
APC Metered Rack PDU Alarm Thresholds Flash Upgradeable High Power Density InfraStruXure Manager compatible Local and web-based monitoring Local Current Monitoring Display Multi-branch power input Remote Current Monitoring Toolless mounting capability Output Connections: IEC 320 C13, IEC 320 C19 |
Output: 230V Input: 400V 3PH Input Connections: IEC 309, 16A, 3P+N+PE Cord Length: 0.91 metres (3 feet) Includes: Installation guide Rack Mounting Brackets Toolless Mounting Kit User Manual 2 years repair or replace Plug Specs |
|||
|
|
|||||
| Switched Rack Power Distribution Units (PDU's) | |||||
|
Switched rack PDUs provide load metering combined with controlled on/off switching by individual outlets for remote power recycling, delayed power sequencing of equipment and outlet use management. - APC Switched Rack Power Distribution Units (PDU's) place rack equipment power control in the hands of the IT Manager. Remote outlet level controls allow power on/off functionality for power recycling to reboot locked-up equipment and to avoid unauthorized use of individual outlets. Power sequencing delays allow users to define the order in which to power up or down attached equipment. Avoid circuit overload during power recovery and extend uptime of critical equipment by prioritising the load shedding. Current metering provides real-time remote monitoring of connected loads. User-defined alarms warn of potential circuit overloads before critical IT failures occur. Users can access, configure, and control Switched rack PDU's through secure Web, SNMP, or Telnet Interfaces and is complimented by APC Centralized Management platforms using InfraStruXure Manager, InfraStruXure Central, Capacity Manager and Change Manager. |
|||||
|
|
|||||
| 230V Input | |||||
|
|
|||||
| AP7920 | APC Rack PDU, Switched, 1U, 12A/208V, 10A/230V, (8) C13 | $918 | |||
|
|
Features: 19" Rack-Mountable, Alarm Thresholds, Flash Upgradeable, Local Current Monitoring Display, Multiple User Support, Power Delays, Remote Current Monitoring, Remote Individual Outlet Control, Remote Management Capabilities. |
||||
|
APC Switched Rack
PDU,
Input: 208V, 230V,
Input Connections: IEC-320 C14,
Cord Length: 1.98 metres (6.5 feet),
Output: 208V, 230V,
Output Connections: 8 x IEC 320 C13. Plug
Specs Includes: Installation Guide, Rack Mounting Brackets, User Manual |
|||||
|
|
|||||
|
|
|||||
| AP7921 | APC Rack PDU, Switched, 1U, 16A, 208/230V, (8) C13 | $1,003 | |||
|
Features: 19 inch Rack-Mountable, Alarm Thresholds, Flash Upgradeable, Local Current Monitoring Display, Multiple User Support, Power Delays, Remote Current Monitoring, Remote Individual Outlet Control, Remote Management Capabilities. |
|||||
| APC Switched Rack
PDU,
Input: 208V, 230V, Input Connections: IEC-320 C20, Cord Length: 2.5 metres (8.2 feet), Output: 208V, 230V, Output Connections:
8 x IEC 320 C13. Plug
Specs Includes: Installation Guide Rack Mounting Brackets User Manual 2 Year Warranty. |
|||||
|
|
|||||
|
|
|||||
| AP7922 | APC Rack PDU, Switched, 2U, 32A, 230V, (16) C13 | $1,076 | |||
|
Features: Alarm Thresholds, Flash Upgradeable, Load indicator LED, Local Current Monitoring Display, Network Management, Power Delay Rack-Mountable, Remote Individual Outlet Control, Single input power source. |
|||||
| APC Switched Rack PDU, Input: 230V, Input Connections: IEC 309 32A 2P+E, Cord Length: 3.05 metres (10 feet), Output: 230V, Output Connections: 16 x IEC 320 C13. Includes: Documentation CD Installation Guide Rack Mounting Brackets. Plug Specs | |||||
|
|
|||||
|
|
|||||
| AP7950 | APC Rack PDU, Switched, Zero U, 10A, 230V, (16) C13 | $1,166 | |||
|
|
The American Power Conversionฎ (APC) AP7950 Switched Rack Power Distribution Unit (PDU) is a network- manageable device that allows individual outlet control. You can configure and monitor it over the network and you can monitor its aggregate current draw both remotely and locally through the digital display. The PDU has sixteen (16) IEC-320-C13 outlets. The 10-foot (3.05-meter) power cord terminates with an IEC-320-C14 connector. The digital display allows you to monitor the aggregate current of the PDU & to establish a network connection using the network port. |
||||
|
APC Switched Rack
PDU Input: 230V Input Connections: IEC-320 C14 Cord Length: 3.05 metres (10 feet) Output: 230V Output Connections: 16 x IEC 320 C13 |
Includes:
Cord Retention Bracket(s) Installation Guide Rack Mounting Brackets Tool less Mounting Kit User Manual |
||||
|
|
|||||
|
|
|||||
| AP7951 | APC Rack PDU, Switched, ZeroU, 16A, 230V, (21) C13 & (3) C19; IEC309 | $1,168 | |||
|
|
The American Power Conversionฎ (APC) AP7951 Switched Rack Power Distribution Unit (PDU) is a network- manageable device that allows individual outlet control of 24 power outlets. You can configure and monitor it over the network and you can monitor its aggregate current draw both remotely and locally through the digital display. The PDU has twenty-one (21) IEC-320-C13 outlets and three (3) IEC-320-C19 outlets. The 3-foot (0.91-meter) power cord terminates with an IEC-309, 230V, single-phase, 16A connector. The digital display allows you to monitor the aggregate current of the PDU and to establish a network connection using the network port. |
||||
|
APC Switched Rack
PDU Input: 230V Input Connections: IEC 309 16A 2P+E Cord Length: 0.91 metres (3 feet) Output: 230V Output Connections: 21 x IEC 320 C13, 3 x IEC 320 C19 |
Includes:
Installation Guide Rack Mounting Brackets Tool less Mounting Kit User Manual Plug Specs |
||||
|
|
|||||
|
|
|||||
| AP7952 | APC Rack PDU, Switched, ZeroU, 16A, 230V, (21) C13 & (3) C19; IEC C20 | $1,168 | |||
|
|
The APC AP7952 Switched Rack Power Distribution Unit (PDU) is a network-manageable device that allows individual outlet control. You can configure & monitor it over the network and you can monitor its aggregate current draw both remotely and locally through the digital display. The PDU has twenty-one (21) IEC-320-C13 outlets and three (3) IEC-320-C19 outlets. The 10-foot (3.05-meter) power cord terminates with an IEC-320-C20 connector. The digital display allows you to monitor the aggregate current of the PDU and to establish a network connection using the network port. |
||||
|
APC Switched Rack PDU Input: 230V Input Connections: IEC-320 C20 Cord Length: 3.05 metres ( 10 feet) Output: 230V Output Connections: 21 x IEC 320 C13, 3 x IEC 320 C19 |
Includes: Cord Retention Bracket(s) Installation Guide Rack Mounting Brackets Tool less Mounting Kit User Manual |
||||
|
|
|||||
|
|
|||||
| AP7953 | APC Rack PDU, Switched, Zero U, 32A, 230V, (21) C13 & (3) C19 | $1,237 | |||
|
|
The APC AP7953 Switched Rack PDU distributes power to devices in the rack. It has a sensor that measures the current used by the PDU and its attached devices. The PDU can be monitored through Web, Telnet, SNMP, SSH, or InfraStruXure Manager interfaces. The Rack PDU has twenty-one (21) IEC-320-C13 outlets and three (3) IEC-320-C19 outlets. The interface uses a digital display that shows aggregate current being used by the Rack PDU. Power cord. The 10-foot (3.05-meter) power cord terminates with a IEC-309, 230V, 32A connector. |
||||
|
APC Switched Rack
PDU Input: 230V Input Connections: IEC 309 32A 2P+E Cord Length: 3.05 metres ( 10 feet) Output Connections: 21 x IEC 320 C13, 3 x IEC 320 C19 |
Includes:
Installation Guide User Manual Plug Specs |
||||
|
|
|||||
|
|
|||||
| AP7954 | APC Switched Rack PDU, ZeroU, 16A, 230V, (21) C13 & (3) C19 | $1,169 | |||
|
|
The APC AP7954 Switched Rack Power Distribution Unit (PDU) is a network-manageable device that allows individual outlet control of 24 power outlets. You can configure and monitor it over the network, and you can monitor its aggregate current draw both remotely and locally through the digital display. The PDU has twenty-one (21) IEC-320-C13 outlets and three (3) IEC-320-C19 outlets. Power cord. The 3.05-meter (10-foot) power cord terminates with an IEC-309, 230V, single-phase, 16A connector. Use the digital display to monitor the aggregate current of the PDU and establish a network connection using the network port. 2 years repair or replace Warranty. |
||||
|
APC Switched Rack
PDU Input: 230V Input Connections: IEC 309 16A 2P+E Cord Length: 3.05 metres ( 10 feet) Output: 230V Output Connections: 21 x IEC 320 C13, 3 x IEC 320 C19 |
Includes:
Cord Retention Bracket(s) Installation Guide Rack Mounting Brackets Tool less Mounting Kit User Manual |
||||
|
|
|||||
|
|
|||||
| 400V 3Phase Input | |||||
|
|
|||||
| AP7957 | APC Rack PDU, Switched, Zero U, 11kW, 230V, (21) C13, (3) C19 | $1,552 | |||
|
|
The American Power Conversion (APCฎ) AP7957 Switched Rack Power Distribution Unit (PDU) is a network- manageable device that allows individual outlet control. You can configure and monitor it over the network, and you can monitor its aggregate current draw both remotely and locally through the digital display. It can be monitored through Web, Telnet, SNMP, SSH, or InfraStruXureฎ Manager interfaces. The Rack PDU has twenty-one (21) IEC-309-C13 outlets and three (3) IEC-309-C19 outlets. The digital display allows you to monitor the aggregate current per phase of the Rack PDU and to establish a network connection using the network port. The 0.91-meter (3-foot) power cord terminates with an IEC-309 16-A connector. |
||||
|
APC Switched Rack PDU Alarm Thresholds Flash Upgradeable High Power Density InfraStruXure Manager compatible Local and web-based monitoring Local Current Monitoring Display Multi-branch power input Remote Management Capabilities Toolless mounting capability Input Connections: IEC 309 16A 3P+N+PE |
Input: 400V 3PH Cord Length: 0.91 metres ( 3 feet ) Output: 230V Output Connections: IEC 320 C13,IEC 320 C19 Includes: Installation guide Rack Mounting brackets Toolless Mounting Kit User Manual 2 years repair or replace Warranty Plug Specs |
||||
|
|
|||||
| Rack Automatic Transfer Switch (ATS) | |||||
|
The only manageable transfer switch in 1U - Provides redundant power to single-corded equipment. |
|||||
|
|
|||||
| Networked 230V Input | |||||
|
|
|||||
| AP7721 | APC Rack ATS, 10A/230V, 12A/208V, C14 in, (12) C13 out | $901 | |||
|
The APC AP7721 Rack Automatic Transfer Switch (ATS) provides reliable, redundant power to single-corded equipment. The Rack ATS has dual input power cords supplying power to the connected load. If the primary source becomes unavailable, the Rack ATS will seamlessly source power from the secondary source without interrupting critical loads. Networked units have built-in network connectivity, which allows for remote management via Web, SNMP, or Telnet interfaces. APC Rack-mount Transfer Switches , Input: 230V , Input Connections: IEC-320 C14 , Output Connections: IEC 320 C13. Includes: Documentation CD, Rack Mounting brackets, RS-232 configuration cable, Warranty card. Plug Specs |
|||||
|
|
|||||
|
|
|||||
| AP7722 | APC Rack ATS, 16A, 230V, (2) IEC 309 in, (1) IEC 309 out | $1,621 | |||
|
The APC AP7722 Automatic Transfer Switch (ATS) is a high-availability switch that provides redundant power to rack-mount equipment. The Automatic Transfer Switch supplies power from a primary input line; if that line becomes unavailable for any reason, the switch automatically begins supplying power from a secondary line. APC Rack Automatic Transfer Switch, Input: 230V, Input Connections: 2 x IEC 309 16A 2P+E, Cord Length: 0.91 metres (3 feet), Output: 230V, Output Connections: 1 x IEC 309 16A (2P+E). Includes: Rack Mounting Brackets User Manual. Plug Specs |
|||||
|
|
|||||
|
|
|||||
| AP7723 | APC Rack ATS, 20A/208V, 16A/230V, C20 in, (8) C13 (1) C19 out | $939 | |||
|
The APC AP7723 Rack Automatic Transfer Switch (ATS) provides reliable, redundant power to single-corded equipment. The Rack ATS has dual input power cords supplying power to the connected load. If the primary source becomes unavailable, the Rack ATS will seamlessly source power from the secondary source without interrupting critical loads. Networked units have built-in network connectivity, which allows for remote management via Web, SNMP, or Telnet interfaces. APC Rack-mount Transfer Switches , Input: 230V , Input Connections: IEC-320 C20 , Output: 230V , Output Connections: IEC 320 C13,IEC 320 C19. Includes: Documentation CD, Rack Mounting brackets, RS-232 configuration. Plug Specs |
|||||
|
|
|||||
|
|
|||||
| AP7724 | APC Rack ATS, 2U 230V, 32A, IEC309-32A In, (16)C13, (2)C19 out | $1,102 | |||
![]() |
APC Rack-mount Transfer Switches , Input: 200V, 208V, 230V , Input Connections: IEC 309 32A 2P+E , Cord Length: 8 feet ( 2.44 meters ) , Output: 230V , Output Connections: IEC 320 C13,IEC 320 C19 |
||||
|
|
|||||
| Rack PDU Accessories | |||||
|
Cord retention brackets and vertical-mount bracket kits to complete rack power distribution solutions. |
|||||
|
|
|||||
| AP7400 | APC Bracket Kit, Zero U PDU, Compaq/Dell | $72 | |||
![]() |
Cord retention brackets and vertical-mount bracket kits to complete rack power distribution solutions Includes: Installation Guide Mounting Hardware Rack Mounting Brackets |
||||
|
|
|||||
|
|
|||||
| AP7404 | APC Bracket Kit, Zero U PDU, Sun Rack 900 | $72 | |||
![]() |
Cord retention brackets and vertical-mount bracket kits to complete rack power distribution solutions Includes: Mounting Hardware Rack Mounting Brackets |
||||
|
|
|||||
|
|
|||||
| AP7768 | APC Bracket Kit, Rear Rails, Rack ATS | $67 | |||
![]() |
Cord retention brackets and vertical-mount bracket kits to complete rack power distribution solutions Includes: Installation guide |
||||
|
|
|||||
|
|
|||||
| AP7769 | APC Cord Retention Bracket for Rack ATS | $64 | |||
![]() |
Cord retention brackets and vertical-mount bracket kits to complete rack power distribution solutions Includes: Installation guide |
||||
|
|
|||||
|
|
|||||
| AP9569 | APC Cord Retention Bracket for Basic Rack PDUs | $116 | |||
| APC Rack PDU Accessories | |||||
|
|
|||||